Cumene Chemical Storage Specifications

Compliant storage and rental solutions for Cumene (C9H12). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Cumene

Cumene is used to manufacture other chemicals such as phenol, acetone, acetophenone, and methyl styrene. It is used as a thinner in paints, lacquers, and enamels. It is a component of high octane motor fuels. Cumene in used in the manufacture of rubber, iron and steel, and pulp and paper.

Structured hazard data

Hazard class
Flammable liquids Category 3
Storage category
Flammable Storage
Flammable
Yes
Flash point
31 C
Storage temperature
See SDS
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Conditions to avoid: Heating. Incompatible materials: rubber

Carcinogenicity (Category 2), H351 Specific target organ toxicity - single exposure (Category 3), Respiratory system, H335 Aspiration hazard (Category 1), H304 Short-term (acute) aquatic hazard (Category 2), H401 Long-term (chronic) aquatic hazard (Category 2), H411

Fire Suppression System

Dry Chemical fire suppression is recommended for Cumene

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Cumene (C9H12). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: SMALL FIRE: Dry chemical, CO2, water spray or regular foam. LARGE FIRE: Water spray, fog or regular foam

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Cumene should account for its listed hazards (Flammable liquids Category 3), climate control needs, and segregation requirements. Conditions to avoid: Heating. Incompatible materials: rubber

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: Melting point/freezing point : -96 °C (-141 °F) - lit. Initial boiling point and boiling range: 152 - 154 °C 306 - 309 °F - lit.

Matched to this chemical

Recommended storage solutions for Cumene

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Cumene be stored?

Store Cumene in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Flammable liquids Category 3). Climate range guidance: Follow the temperature range listed on the manufacturer SDS.. Compatibility notes: Conditions to avoid: Heating. Incompatible materials: rubber US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Cumene flammable?

Yes — Cumene is flagged as a flammable hazard in this database (Yes). Flash point: 31 C. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Cumene?

Cumene is listed as: Flammable liquids Category 3. Carcinogenicity (Category 2), H351 Specific target organ toxicity - single exposure (Category 3), Respiratory system, H335 Aspiration hazard (Category 1), H304 Short-term (acute) aquatic hazard (Category 2), H401 Long-term (chronic) aquatic hazard (Category 2), H411

What fire suppression is recommended for Cumene?

Dry Chemical fire suppression is generally recommended for Cumene (C9H12). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Cumene storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Cumene. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.