FireSAFE 4X
- 4-Hour Fire-Rated
- 8 ft x 40 ft
- 57 Barrels
- 55 Gal Storage Drums
- 228 Square Feet storage
Compliant storage and rental solutions for Dichloropropene, 1, 3- (C3H4Cl2). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Dichloropropene is an abundant pesticide used on crops across the United States to control pests.
Acute oral toxicity Category 4 Acute Inhalation Toxicity - Vapors Category 4 Skin Corrosion/Irritation Category 2 Serious Eye Damage/Eye Irritation Category 2 Specific target organ toxicity (single exposure) Category 3
Dry Chemical fire suppression is recommended for Dichloropropene, 1, 3-
Guidance: Dry Chemical fire suppression is generally recommended for Dichloropropene, 1, 3- (C3H4Cl2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Additional extinguishing notes: SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam. LARGE FIRE: Water spray, fog or alcohol-resistant foam.
Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.
Compliant storage and rental solutions for Dichloropropene, 1, 3- should account for its listed hazards (Category 2 Flammable Liquid), climate control needs, and segregation requirements. OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, and NITRATES); STRONG ACIDS
Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.
Properties: Suitable Extinguishing Media Carbon dioxide (CO 2). Dry chemical. Water mist may be used to cool closed containers. Chemical foam. Water mist may be used to cool closed containers. Unsuitable Extinguishing Media No information available Flash Point 20 °C / 68 °F Method - No information available Autoignition Temperature 480 °C / 896 °F Explosion Limits Upper 14.5% Lower 3.4% Sensitivity to Mechanical Impact No information available Sensitivity to Static Discharge No information available
Matched to this chemical
Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.



Material handling
US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

Large-volume tote storage with forklift-ready handling inside compliant buildings.
Explore solution
Drum and pallet-adjacent workflows sized for secondary containment and segregation.
Explore solution
Pallet-in, pallet-out layouts for packaged chemicals and rack-ready inventory.
Explore solution
Locker and cabinet-scale storage for cans, jars, and other small-format chemicals.
Explore solutionWe have solutions designed for your workflow process needs.
Store Dichloropropene, 1, 3- in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Category 2 Flammable Liquid). Climate range guidance: Follow the temperature range listed on the manufacturer SDS.. Compatibility notes: OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, and NITRATES); STRONG ACIDS US Hazmat Rentals provides compliant chemical storage buildings available for rental.
Yes — Dichloropropene, 1, 3- is flagged as a flammable hazard in this database (Yes). Flash point: 20 C. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.
Dichloropropene, 1, 3- is listed as: Category 2 Flammable Liquid. Acute oral toxicity Category 4 Acute Inhalation Toxicity - Vapors Category 4 Skin Corrosion/Irritation Category 2 Serious Eye Damage/Eye Irritation Category 2 Specific target organ toxicity (single exposure) Category 3
Dry Chemical fire suppression is generally recommended for Dichloropropene, 1, 3- (C3H4Cl2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Dichloropropene, 1, 3-. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.