Epichlorohydrin Chemical Storage Specifications

Compliant storage and rental solutions for Epichlorohydrin (C3H5ClO). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Epichlorohydrin

Epichlorohydrin is also used in the manufacture of synthetic glycerine, textiles, paper, inks and dyes.

Structured hazard data

Hazard class
Category 3 Flammable Liquid
Storage category
Flammable Storage
Flammable
Yes
Flash point
33 °C / 91.4 °F
Storage temperature
See SDS
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Epichlorohydrin may react violently or explosively with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE

Acute oral toxicity Category 3 Acute dermal toxicity Category 3 Skin Corrosion/Irritation Category 1 B Serious Eye Damage/Eye Irritation Category 1 Skin Sensitization Category 1 Carcinogenicity Category 1B

Fire Suppression System

Dry Chemical fire suppression is recommended for Epichlorohydrin

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Epichlorohydrin (C3H5ClO). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: dry chemical, foam or carbon dioxide.

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Epichlorohydrin should account for its listed hazards (Category 3 Flammable Liquid), climate control needs, and segregation requirements. Epichlorohydrin may react violently or explosively with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: Physical State Liquid Appearance Light yellow Odor sweet Odor Threshold No information available pH No information available Melting Point/Range -57 °C / -70.6 °F Boiling Point/Range 114 °C / 237.2 °F Flash Point 33 °C / 91.4 °F Evaporation Rate No information available Flammability (solid,gas) Not applicable Flammability or explosive limits Upper 21.0% Lower 3.8% Vapor Pressure No information available Vapor Density No information available Specific Gravity 1.183 Solubility No information available

Matched to this chemical

Recommended storage solutions for Epichlorohydrin

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Epichlorohydrin be stored?

Store Epichlorohydrin in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Category 3 Flammable Liquid). Climate range guidance: Follow the temperature range listed on the manufacturer SDS.. Compatibility notes: Epichlorohydrin may react violently or explosively with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Epichlorohydrin flammable?

Yes — Epichlorohydrin is flagged as a flammable hazard in this database (Yes). Flash point: 33 °C / 91.4 °F. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Epichlorohydrin?

Epichlorohydrin is listed as: Category 3 Flammable Liquid. Acute oral toxicity Category 3 Acute dermal toxicity Category 3 Skin Corrosion/Irritation Category 1 B Serious Eye Damage/Eye Irritation Category 1 Skin Sensitization Category 1 Carcinogenicity Category 1B

What fire suppression is recommended for Epichlorohydrin?

Dry Chemical fire suppression is generally recommended for Epichlorohydrin (C3H5ClO). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Epichlorohydrin storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Epichlorohydrin. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.