Mercuric Cyanide Chemical Storage Specifications

Compliant storage and rental solutions for Mercuric Cyanide (Hg(CN)2). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Non-flammableNon-Flammable Storage

Chemical formula

About Mercuric Cyanide

Mercuric Cyanide is an odorless, clear, or white, crystalline (sand-like) powder. It is used in germicidal soaps, photography, and making Cyanogen gas.

Structured hazard data

Hazard class
See SDS
Storage category
Non-Flammable Storage
Flammable
No
Flash point
See SDS
Storage temperature
Dark, cool environment
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Incompatible with strong oxidizing agents. Fusion with metal chlorates, perchlorates, nitrates or nitrites can cause violent explosions

Acute toxicity, Oral (Category 2), H300 Acute toxicity, Inhalation (Category 2), H330 Acute toxicity, Dermal (Category 1), H310 Specific target organ toxicity - repeated exposure (Category 2), H373 Short-term (acute) aquatic hazard (Category 1), H400 Long-term (chronic) aquatic hazard (Category 1), H410

Fire Suppression System

Dry Chemical fire suppression is recommended for Mercuric Cyanide

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Mercuric Cyanide (Hg(CN)2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Mercuric Cyanide should account for its listed hazards, climate control needs (Dark, cool environment ), and segregation requirements. Incompatible with strong oxidizing agents. Fusion with metal chlorates, perchlorates, nitrates or nitrites can cause violent explosions

Review Segregated storage for incompatible chemicals and How the NFPA 704 hazard rating works when designing fire rating, containment, and building selection.

Properties: a) Appearance Form: solid Color: white

Matched to this chemical

Recommended storage solutions for Mercuric Cyanide

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Non-fire-rated0 HourChemical Storage Shipping

    BoxSAFE CX

    • Non Fire-Rated
    • 8 ft x 40 ft x 8' 5"
    • 50 Qty 55 Gallon Drums
    • 9 Pallets or Totes
    • 302 Square Feet storage
    View product
  • Non-fire-rated0 HourChremical Storage

    Non Fire-Rated

    • 0-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    View product
  • Non-fire-rated0 HourChremical Storage

    Non Fire-Rate

    • 0-Hour Fire-Rated
    • 8 ft x 20 ft
    • 27 Barrels
    • 55 Gal Storage Drums
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Mercuric Cyanide be stored?

Store Mercuric Cyanide in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: Dark, cool environment. Compatibility notes: Incompatible with strong oxidizing agents. Fusion with metal chlorates, perchlorates, nitrates or nitrites can cause violent explosions US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Mercuric Cyanide flammable?

Mercuric Cyanide is not flagged as flammable in this database (No). Still verify the SDS and store in compliant containment for its listed hazard class.

What hazard class is Mercuric Cyanide?

Mercuric Cyanide is listed as: Consult the SDS and applicable hazard classification. Acute toxicity, Oral (Category 2), H300 Acute toxicity, Inhalation (Category 2), H330 Acute toxicity, Dermal (Category 1), H310 Specific target organ toxicity - repeated exposure (Category 2), H373 Short-term (acute) aquatic hazard (Category 1), H400 Long-term (chronic) aquatic hazard (Category 1), H410

What fire suppression is recommended for Mercuric Cyanide?

Dry Chemical fire suppression is generally recommended for Mercuric Cyanide (Hg(CN)2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Mercuric Cyanide storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Mercuric Cyanide. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.