Methylamine, Anhydrous Chemical Storage Specifications

Compliant storage and rental solutions for Methylamine, Anhydrous (CH3NH2). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Methylamine, Anhydrous

Methylamine, like industrial ammonia, has an incredibly wide array of uses. It is used in both organic synthesis and the tanning and dyeing of leather, but is also used: As an intermediate for accelerators, pharmaceuticals, insecticides, fungicides, surface active cleaning agents. In the dyeing of acetate textiles.

Structured hazard data

Hazard class
Flammable Gases Catergory 1
Storage category
Flammable Storage
Flammable
Yes
Flash point
See SDS
Storage temperature
Ambient
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Oxidizers

GASES UNDER PRESSURE - Liquefied gas ACUTE TOXICITY (inhalation) - Category 4 SKIN IRRITATION - Category 2 SERIOUS EYE DAMAGE - Category 1 SPECIFIC TARGET ORGAN TOXICITY (SINGLE EXPOSURE) (Narcotic effects) - Category 3

Fire Suppression System

Dry Chemical fire suppression is recommended for Methylamine, Anhydrous

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Methylamine, anhydrous (CH3NH2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Methylamine, anhydrous should account for its listed hazards (Flammable Gases Catergory 1), climate control needs (Ambient), and segregation requirements. Oxidizers

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: Melting point: -93 C. Boiling Point: -6 C.

Matched to this chemical

Recommended storage solutions for Methylamine, Anhydrous

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Methylamine, anhydrous be stored?

Store Methylamine, anhydrous in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Flammable Gases Catergory 1). Climate range guidance: Ambient. Compatibility notes: Oxidizers US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Methylamine, anhydrous flammable?

Yes — Methylamine, anhydrous is flagged as a flammable hazard in this database (Yes). Flash point: see SDS. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Methylamine, anhydrous?

Methylamine, anhydrous is listed as: Flammable Gases Catergory 1. GASES UNDER PRESSURE - Liquefied gas ACUTE TOXICITY (inhalation) - Category 4 SKIN IRRITATION - Category 2 SERIOUS EYE DAMAGE - Category 1 SPECIFIC TARGET ORGAN TOXICITY (SINGLE EXPOSURE) (Narcotic effects) - Category 3

What fire suppression is recommended for Methylamine, anhydrous?

Dry Chemical fire suppression is generally recommended for Methylamine, anhydrous (CH3NH2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Methylamine, anhydrous storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Methylamine, anhydrous. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.