BoxSAFE CX
- Non Fire-Rated
- 8 ft x 40 ft x 8' 5"
- 50 Qty 55 Gallon Drums
- 9 Pallets or Totes
- 302 Square Feet storage
Compliant storage and rental solutions for Nitroaniline, P- (C6H6N202). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.
4-Nitroaniline, p-nitroaniline or 1-amino-4-nitrobenzene is an organic compound with the formula C₆H₆N₂O₂. A yellow solid, it is one of three isomers of nitroaniline
Acute toxicity, Oral (Category 3) Acute toxicity, Inhalation (Category 3) Acute toxicity, Dermal (Category 3) Specific target organ toxicity - repeated exposure (Category 2) Short-term (acute) aquatic hazard (Category 3) Long-term (chronic) aquatic hazard (Category 3)
Dry Chemical fire suppression is recommended for Nitroaniline, P-
Guidance: Dry Chemical fire suppression is generally recommended for Nitroaniline, p- (C6H6N202). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Additional extinguishing notes: Suitable extinguishing media Water Foam Carbon dioxide (CO2) Dry powder
Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.
Compliant storage and rental solutions for Nitroaniline, p- should account for its listed hazards, climate control needs (Recommended storage temperature: 15 – 25 °C), and segregation requirements. Incompatible materials rubber, various plastics
Review Segregated storage for incompatible chemicals and How the NFPA 704 hazard rating works when designing fire rating, containment, and building selection.
Properties: Melting point/freezing point: 146 - 149 °C (295 - 300 °F) - lit. Initial boiling point and boiling range: 260 °C 500 °F at 133 hPa - lit.
Matched to this chemical
Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.



Material handling
US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

Large-volume tote storage with forklift-ready handling inside compliant buildings.
Explore solution
Drum and pallet-adjacent workflows sized for secondary containment and segregation.
Explore solution
Pallet-in, pallet-out layouts for packaged chemicals and rack-ready inventory.
Explore solution
Locker and cabinet-scale storage for cans, jars, and other small-format chemicals.
Explore solutionWe have solutions designed for your workflow process needs.
Store Nitroaniline, p- in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: Recommended storage temperature: 15 – 25 °C. Compatibility notes: Incompatible materials rubber, various plastics US Hazmat Rentals provides compliant chemical storage buildings available for rental.
Nitroaniline, p- is not flagged as flammable in this database (No). Still verify the SDS and store in compliant containment for its listed hazard class.
Nitroaniline, p- is listed as: Consult the SDS and applicable hazard classification. Acute toxicity, Oral (Category 3) Acute toxicity, Inhalation (Category 3) Acute toxicity, Dermal (Category 3) Specific target organ toxicity - repeated exposure (Category 2) Short-term (acute) aquatic hazard (Category 3) Long-term (chronic) aquatic hazard (Category 3)
Dry Chemical fire suppression is generally recommended for Nitroaniline, p- (C6H6N202). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Nitroaniline, p-. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.