Nitrocellulose, Alcohol Wet Chemical Storage Specifications

Compliant storage and rental solutions for Nitrocellulose, Alcohol Wet ((C 6H 9(NO 2)O 5) n). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Nitrocellulose, Alcohol Wet

A white solid mixed with ethanol or another solvent to form a slurry. A mixture of the dinitrates and trinitrate of cellulose. Exposure to heat may evaporate the solvent leaving a residue that is subject to self-accelerating decomposition and may explode if confined or present in large quantities.

Structured hazard data

Hazard class
Flammable liquids Category 1
Storage category
Flammable Storage
Flammable
Yes
Flash point
-47 °C / -52.6 °F
Storage temperature
The maximum storage temperature of 40 °C
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Incompatible materials Strong acids. Strong bases. Strong oxidizing agents

Acute toxicity - Oral Category 4 Skin corrosion/irritation Category 2 Serious eye damage/eye irritation Category 2A Reproductive toxicity Category 1A Specific target organ toxicity (single exposure) Category 3 Specific target organ toxicity (repeated exposure) Category 1

Fire Suppression System

Dry Chemical fire suppression is recommended for Nitrocellulose, Alcohol Wet

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Nitrocellulose, alcohol wet ((C 6H 9(NO 2)O 5) n). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: Suitable Extinguishing Media Dry chemical. Carbon dioxide (CO2). water spray. Alcohol resistant foam. Large Fire CAUTION: Use of water spray when fighting fire may be inefficient.

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Nitrocellulose, alcohol wet should account for its listed hazards (Flammable liquids Category 1), climate control needs (The maximum storage temperature of 40 °C), and segregation requirements. Incompatible materials Strong acids. Strong bases. Strong oxidizing agents

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: Boiling point.: Ethanol: 78.3 oC Isopropanol: 82.3 o

Matched to this chemical

Recommended storage solutions for Nitrocellulose, Alcohol Wet

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Nitrocellulose, alcohol wet be stored?

Store Nitrocellulose, alcohol wet in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Flammable liquids Category 1). Climate range guidance: The maximum storage temperature of 40 °C. Compatibility notes: Incompatible materials Strong acids. Strong bases. Strong oxidizing agents US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Nitrocellulose, alcohol wet flammable?

Yes — Nitrocellulose, alcohol wet is flagged as a flammable hazard in this database (Yes). Flash point: -47 °C / -52.6 °F. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Nitrocellulose, alcohol wet?

Nitrocellulose, alcohol wet is listed as: Flammable liquids Category 1. Acute toxicity - Oral Category 4 Skin corrosion/irritation Category 2 Serious eye damage/eye irritation Category 2A Reproductive toxicity Category 1A Specific target organ toxicity (single exposure) Category 3 Specific target organ toxicity (repeated exposure) Category 1

What fire suppression is recommended for Nitrocellulose, alcohol wet?

Dry Chemical fire suppression is generally recommended for Nitrocellulose, alcohol wet ((C 6H 9(NO 2)O 5) n). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Nitrocellulose, alcohol wet storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Nitrocellulose, alcohol wet. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.