Nitromethane Chemical Storage Specifications

Compliant storage and rental solutions for Nitromethane (CH3NO2). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Nitromethane

Nitromethane is a colorless, oily liquid with a mild disagreeable or fruity odor. It is used as a propellant, fuel additive, rocket fuel, and solvent, and in making dyes, textiles, pharmaceuticals, and explosives.

Structured hazard data

Hazard class
See SDS
Storage category
Flammable Storage
Flammable
Yes
Flash point
35 °C (95 °F) - closed cup - ISO 1523
Storage temperature
Ambient
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Nitromethane reacts violently with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE)

Flammable liquids (Category 3), H226 Acute toxicity, Oral (Category 4), H302 Acute toxicity, Inhalation (Category 4), H332 Carcinogenicity (Category 2), H351 Reproductive toxicity (Category 2), H361

Fire Suppression System

Dry Chemical fire suppression is recommended for Nitromethane

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Nitromethane (CH3NO2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: Water Foam Carbon dioxide (CO2) Dry powder

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Nitromethane should account for its listed hazards, climate control needs (Ambient), and segregation requirements. Nitromethane reacts violently with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE)

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: a) Appearance Form: liquid Color: clear, colorless b) Odor characteristic c) Odor Threshold No data available d) pH No data available e) Melting point/freezing point Melting point/range: -29 °C (-20 °F) - lit. f) Initial boiling point and boiling range 101.2 °C 214.2 °F - lit. g) Flash point 35 °C (95 °F) - closed cup - ISO 1523

Matched to this chemical

Recommended storage solutions for Nitromethane

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Nitromethane be stored?

Store Nitromethane in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: Ambient. Compatibility notes: Nitromethane reacts violently with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE) US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Nitromethane flammable?

Yes — Nitromethane is flagged as a flammable hazard in this database (Yes). Flash point: 35 °C (95 °F) - closed cup - ISO 1523. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Nitromethane?

Nitromethane is listed as: Consult the SDS and applicable hazard classification. Flammable liquids (Category 3), H226 Acute toxicity, Oral (Category 4), H302 Acute toxicity, Inhalation (Category 4), H332 Carcinogenicity (Category 2), H351 Reproductive toxicity (Category 2), H361

What fire suppression is recommended for Nitromethane?

Dry Chemical fire suppression is generally recommended for Nitromethane (CH3NO2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Nitromethane storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Nitromethane. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.