Compliant storage and rental solutions for Nitrophenol, P- (C6H7NO4). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.
used to manufacture drugs, fungicides, insecticides, and dyes and to darken leather. Acute (short-term) inhalation or ingestion of 4-nitrophenol in humans causes headaches, drowsiness, nausea, and cyanosis (blue color in lips, ears, and fingernails). Contact with eyes causes irritation in humans.
Acute toxicity, Oral (Category 3), H301 Acute toxicity, Inhalation (Category 4), H332 Acute toxicity, Dermal (Category 4), H312 Specific target organ toxicity - repeated exposure (Category 2), H373 Acute aquatic toxicity (Category 2), H401
Dry Chemical fire suppression is recommended for Nitrophenol, P-
Guidance: Dry Chemical fire suppression is generally recommended for Nitrophenol, p- (C6H7NO4). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Additional extinguishing notes: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.
Compliant storage and rental solutions for Nitrophenol, p- should account for its listed hazards, climate control needs (−0 °C), and segregation requirements. -Nitrophenol is not compatible with STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE); OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES
Review Segregated storage for incompatible chemicals and Organic peroxide storage building when designing fire rating, containment, and building selection.
Properties: d) pH 4.4 at 5.00000 g/l at 24.0 °C (75.2 °F) e) Melting point/freezing point Melting point/range: 110 - 115 °C (230 - 239 °F) - lit. f) Initial boiling point and boiling range 279 °C (534 °F) - lit. g) Flash point 169.0 °C (336.2 °F) - closed cup
Matched to this chemical
Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.



Material handling
US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

Large-volume tote storage with forklift-ready handling inside compliant buildings.
Explore solution
Drum and pallet-adjacent workflows sized for secondary containment and segregation.
Explore solution
Pallet-in, pallet-out layouts for packaged chemicals and rack-ready inventory.
Explore solution
Locker and cabinet-scale storage for cans, jars, and other small-format chemicals.
Explore solutionWe have solutions designed for your workflow process needs.
Store Nitrophenol, p- in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: −0 °C. Compatibility notes: -Nitrophenol is not compatible with STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE); OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES US Hazmat Rentals provides compliant chemical storage buildings available for rental.
Nitrophenol, p- is not flagged as flammable in this database (No). Still verify the SDS and store in compliant containment for its listed hazard class.
Nitrophenol, p- is listed as: Consult the SDS and applicable hazard classification. Acute toxicity, Oral (Category 3), H301 Acute toxicity, Inhalation (Category 4), H332 Acute toxicity, Dermal (Category 4), H312 Specific target organ toxicity - repeated exposure (Category 2), H373 Acute aquatic toxicity (Category 2), H401
Dry Chemical fire suppression is generally recommended for Nitrophenol, p- (C6H7NO4). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Nitrophenol, p-. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.