Octane Chemical Storage Specifications

Compliant storage and rental solutions for Octane (C₈H₁₈). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Octane

Octane is a gasoline additive that is needed for the proper functioning of modern engines. Octane sources have taken many forms throughout the years, both renewable and petroleum-based. They include lead, methyl tertiary butyl ether (MTBE), benzene, toluene, ethyl-benzene and xylene (BTEX), and ethanol (a biofuel).

Structured hazard data

Hazard class
See SDS
Storage category
Flammable Storage
Flammable
Yes
Flash point
13 °C (55 °F) - closed cup
Storage temperature
<80 F
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Octane is not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); NITRIC ACID; and COMBUSTIBLE MATERIALS.

Flammable liquids (Category 2), H225 Skin irritation (Category 2), H315 Specific target organ toxicity - single exposure (Category 3), Central nervous system, H336 Aspiration hazard (Category 1), H304 Short-term (acute) aquatic hazard (Category 1), H400 Long-term (chronic) aquatic hazard (Category 1), H410

Fire Suppression System

Dry Chemical fire suppression is recommended for Octane

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Octane (C₈H₁₈). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: Carbon dioxide (CO2) Foam Dry powder

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Octane should account for its listed hazards, climate control needs (<80 F), and segregation requirements. Octane is not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); NITRIC ACID; and COMBUSTIBLE MATERIALS.

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: e) Melting point/freezing point Melting point/range: -57 °C (-71 °F) - lit. f) Initial boiling point and boiling range 125 - 127 °C 257 - 261 °F - lit. g) Flash point 13 °C (55 °F) - closed cup h) Evaporation rate No data available i) Flammability (solid, gas) No data available j) Upper/lower flammability or explosive limits Upper explosion limit: 6.5 %(V) Lower explosion limit: 0.96 %(V) k) Vapor pressure 14.7 hPa at 20.0 °C (68.0 °F)

Matched to this chemical

Recommended storage solutions for Octane

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Octane be stored?

Store Octane in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: <80 F. Compatibility notes: Octane is not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); NITRIC ACID; and COMBUSTIBLE MATERIALS. US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Octane flammable?

Yes — Octane is flagged as a flammable hazard in this database (Yes). Flash point: 13 °C (55 °F) - closed cup. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Octane?

Octane is listed as: Consult the SDS and applicable hazard classification. Flammable liquids (Category 2), H225 Skin irritation (Category 2), H315 Specific target organ toxicity - single exposure (Category 3), Central nervous system, H336 Aspiration hazard (Category 1), H304 Short-term (acute) aquatic hazard (Category 1), H400 Long-term (chronic) aquatic hazard (Category 1), H410

What fire suppression is recommended for Octane?

Dry Chemical fire suppression is generally recommended for Octane (C₈H₁₈). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Octane storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Octane. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.