
FireSAFE 4X
- 4-Hour Fire-Rated
- 8 ft x 40 ft
- 57 Barrels
- 55 Gal Storage Drums
- 228 Square Feet storage
Compliant storage and rental solutions for Propyltrichlorosilane (C3H7Cl3Si). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.
Used as intermediate for silicones
Skin Corrosion/Irritation Category 1 B Serious Eye Damage/Eye Irritation Category 1 Specific target organ toxicity (single exposure) Category 3 Target Organs - Respiratory system.
Dry Chemical fire suppression is recommended for Propyltrichlorosilane
Guidance: Dry Chemical fire suppression is generally recommended for Propyltrichlorosilane (C3H7Cl3Si). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Additional extinguishing notes: Water mist may be used to cool closed containers. CO 2, dry chemical, dry sand, alcohol-resistant foam.
Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.
Compliant storage and rental solutions for Propyltrichlorosilane should account for its listed hazards (Flammable liquids Category 3), climate control needs (Store under indert atmosphere), and segregation requirements. Strong oxidizing agents. Water. Alcohols. Bases.
Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.
Properties: Physical State Liquid Appearance No information available Odor No information available Odor Threshold No information available pH No information available Melting Point/Range No data available Boiling Point/Range 123 - 124 °C / 253.4 - 255.2 °F Flash Point 31 °C / 87.8 °F Evaporation Rate No information available Flammability (solid,gas) Not applicable Flammability or explosive limits Upper No data available Lower No data available Vapor Pressure 38.4 mbar @ 20°C
Matched to this chemical
Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.



Material handling
US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

Large-volume tote storage with forklift-ready handling inside compliant buildings.
Explore solution
Drum and pallet-adjacent workflows sized for secondary containment and segregation.
Explore solution
Pallet-in, pallet-out layouts for packaged chemicals and rack-ready inventory.
Explore solution
Locker and cabinet-scale storage for cans, jars, and other small-format chemicals.
Explore solutionWe have solutions designed for your workflow process needs.
Store Propyltrichlorosilane in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Flammable liquids Category 3). Climate range guidance: Store under indert atmosphere. Compatibility notes: Strong oxidizing agents. Water. Alcohols. Bases. US Hazmat Rentals provides compliant chemical storage buildings available for rental.
Yes — Propyltrichlorosilane is flagged as a flammable hazard in this database (Yes). Flash point: 31 °C / 87.8 °F. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.
Propyltrichlorosilane is listed as: Flammable liquids Category 3. Skin Corrosion/Irritation Category 1 B Serious Eye Damage/Eye Irritation Category 1 Specific target organ toxicity (single exposure) Category 3 Target Organs - Respiratory system.
Dry Chemical fire suppression is generally recommended for Propyltrichlorosilane (C3H7Cl3Si). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Propyltrichlorosilane. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.